{"title":"Expansion Cards","description":"","products":[{"product_id":"2-port-100-gbe-qsfp28-card","title":"2-Port 100 GbE (100GB Total Bandwidth) QSFP28 Card","description":"\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003e100 GIGABIT ETHERNET LOW PROFILE CARD DUAL-PORT FIBER \u0026amp; DAC QSFP28 NETWORK INTERFACE CARD INTEL\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e E810-CAM2 BASED \u003c\/h2\u003e\n\u003ch4 style=\"text-align: left;\"\u003eHIGH-PERFORMANCE, DUAL-PORT 100 GBE ETHERNET ADAPTER, COMPATIBLE WITH THE NETGATE\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e 8300\u003c\/h4\u003e\n\u003cp style=\"text-align: left;\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv class=\"des_text\"\u003e\n\u003cp\u003eThis 100 Gigabit Ethernet Dual-Port QSFP28 Computing PCI Express Network Interface Card offers simple integration into any PCI Express x16 slot to interface with 100 Gigabit networks. The performance is optimized so that system I\/O is not the bottleneck in high-performance networking applications. Based on the Intel E810-CAM2 Ethernet controller, the card has two fully integrated 100G Ethernet Ports, enhanced programmable packet processing pipeline, virtualization (Enhanced SR-IOV support with up to 256 VFs, backward compatibility VF driver support), new features for the communications market (fine-grained scheduler, transmit head drop support, adjustment of credits according to different headers, enhanced QoS, enhanced burst control) and RDMA (iWARP and RoCEv2).\u003cbr\u003e\u003cbr\u003eThis 100 Gigabit Ethernet PCI-Express Network Interface Card is the ideal solution for implementing multiple network segments, mission-critical high-powered networking applications, and environments within high-performance servers.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"text-align: left;\"\u003eKEY FEATURES:\u003c\/h2\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e2x QSFP28 ports\u003c\/li\u003e\n\u003cli\u003e100 Gbps total BW\u003c\/li\u003e\n\u003cli\u003eSERDES capable of 25G NRZ\u003c\/li\u003e\n\u003cli\u003eSupports up to 8 ports: 2x100G (SR4\/LR4) \/ 8x10G ( SR\/LR) via breakout cable\u003c\/li\u003e\n\u003cli\u003eAuto-negotiation with auto-detect.\u003c\/li\u003e\n\u003cli\u003eIEEE1588 Precision Time Protocol\u003c\/li\u003e\n\u003cli\u003eSupports Direct Attached Copper cable\u003c\/li\u003e\n\u003cli\u003eSupports QSFP28 100G transceivers\u003c\/li\u003e\n\u003cli\u003eBased on Intel E810-CAM2\u003c\/li\u003e\n\u003cli\u003eLow Profile\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHost Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePCIe x16 lanes from\/to host via gold fingers of edge card\u003c\/li\u003e\n\u003cli\u003eSupport PCI Express Base Specification Revision 4.0, 16GT\/s, 8GT\/s, 5GT\/s or 2.5GT\/s Compliance with PCIe spec 4.0 currently at draft 0.9\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLAN and Virtualization Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100 Gbps throughput (each of Tx and Rx)\u003c\/li\u003e\n\u003cli\u003eParses up to 504B from packet header\u003c\/li\u003e\n\u003cli\u003e768 switch ports (VSIs)\u003c\/li\u003e\n\u003cli\u003eProgrammable forwarding rules\u003c\/li\u003e\n\u003cli\u003eVirtualization\n\u003cul\u003e\n\u003cli\u003eHost virtualization via VMQ and SR-IOV\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003eSupport for offloads including Geneve, VxLAN and NVGRE\u003c\/li\u003e\n\u003cli\u003e256 SR-IOV Virtual Functions\u003c\/li\u003e\n\u003cli\u003eStateless offloads for tunneled packets (network virtualization support)\u003c\/li\u003e\n\u003cli\u003eMalicious VF protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eRDMA\n\u003cul\u003e\n\u003cli\u003eiWARP and RoCE v2\u003c\/li\u003e\n\u003cli\u003e256K Queue Pairs (QPs)\u003c\/li\u003e\n\u003cli\u003eSend Queue Push Mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eQoS\n\u003cul\u003e\n\u003cli\u003eWFQ Transmit scheduler with 9 programmable layers\u003c\/li\u003e\n\u003cli\u003ePipeline sharing and starvation avoidance\u003c\/li\u003e\n\u003cli\u003eUp to 32 Congestion Domains in the Tx and Rx paths\u003c\/li\u003e\n\u003cli\u003eQoS via 802.1p PCP or Differentiated services DSCP value\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRx Packet buffer supports at least 3 no-drop flow control events, shared among ports\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"text-align: left;\"\u003eSPECIFICATION:\u003c\/h2\u003e\n\u003ctable style=\"width: 100%;\" border=\"1\" cellspacing=\"1\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eQSFP28 100 GIGABIT ETHERNET ADAPTER TECHNICAL SPECIFICATIONS:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eQSFP28 (Small Form Factor Pluggable) supports:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e100GBASE: CAUI-4 interfaces conforming to IEEE 802.3bm and IEEE 802.3bj standards, to support 100GBase-SR4, 100GBase-LR4 and 100GBase-CR4 interfaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-SR4\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eFiber 100 Gigabit Ethernet, 100GBASE-SR4 (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-SR4\u003cbr\u003eData Transfer Rate:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e103.125 GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-SR4\u003cbr\u003eCable type and Operating distance up to:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eMultimode fiber: 62.5um, (OM4) 100m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-LR4\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eFiber 100 Gigabit Ethernet, 100GBASE-LR4 (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-LR4 QSFP28\u003cbr\u003eData Transfer Rate:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e103.1 GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-LR4 QSFP28\u003cbr\u003eCables and Operating distance Up to:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eSingle-Mode: 10km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOPERATING SYSTEMS SUPPORT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOperating system support:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eWindows\u003cbr\u003eLinux\u003cbr\u003eFreeBSD\u003cbr\u003eVMware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eGENERAL TECHNICAL SPECIFICATIONS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eInterface Standard:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003ePCI-Express Base Specification Revision 4.0 ( 16 GTs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e(2) QSFP28 Cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eBoard Size:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLow profile short add-in card 167.64mm X 68.91mm (6.60”X 2.713”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLPHL, Low-Profile, Half-Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003ePCI Express Card Type:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eX16 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOn Board Connector Voltage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e+12V +\/-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003ePCI Connector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eGold Finger: X16 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eControllers:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eIntel E810-CAM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eHolder:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eMetal Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e0°C – 45°C (32°F – 113°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e-40°C–65°C (-40°F–149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e0%–90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eRegulatory Certifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eCE, FCC Class B, ROHS, TAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"text-transform: none;\"\u003eLEDs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eLEDs:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e\n\u003cp\u003eTwo LEDs per port to indicate link status and speed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e100\/25\/10 Gbps link speed LED:\u003cbr\u003eLED on = link is up\u003cbr\u003e100Gbps (Green)\u003cbr\u003e25G\/10Gbps (Yellow)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eLink\/Act 100\/25\/10 Gbps LED (Green):\u003cbr\u003eSolid = link\u003cbr\u003eBlink = activity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eLEDs location:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLEDs are on the PCB, visible via light guides through the metal bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"text-align: left;\"\u003e\n\u003cbr\u003eADDITIONAL INFORMATION:\u003c\/h3\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u003cstrong\u003eWorks with the Netgate 8300 and other systems that support PCI-e 4.0 low profile short add-in cards.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUse with the Netgate 8300 with TNSR for high speed network transfer applications.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e* Features and throughput are subject to hardware and operating system support. \u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: left;\"\u003eWARRANTY AND SUPPORT INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003eNo returns\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eOne year manufacturer's warranty\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eAll specifications are subject to change without notice.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"shop.netgate.com","offers":[{"title":"Default Title","offer_id":43351192698982,"sku":"E14","price":850.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/3173\/6166\/files\/P4CG2I81_angle_1500x1500_2.jpg?v=1759265373"},{"product_id":"2-port-25-gbe-sfp28-card","title":"2-Port 25 GbE (50GB Total Bandwidth) SFP28 Card","description":"\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003e25 GIGABIT ETHERNET LOW PROFILE CARD DUAL-PORT FIBER \u0026amp; DAC SFP28 NETWORK INTERFACE CARD INTEL\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e E810 BASED \u003c\/h2\u003e\n\u003ch4 style=\"text-align: left;\"\u003eHIGH-PERFORMANCE, DUAL-PORT SFP28 25\/10\/1 GIGABIT ETHERNET PCI EXPRESS SERVER ADAPTER\u003c\/h4\u003e\n\u003cp style=\"text-align: left;\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv class=\"des_text\"\u003e\n\u003cp\u003eThis 25 Gigabit Ethernet Dual-Port SFP28 Computing PCI Express Network Interface Card offers simple integration into any PCI Express X16 slot to interface with 25 Gigabit networks. The performance is optimized so that system I\/O is not the bottleneck in high-performance networking applications. Based on the Intel E810 XXVAM2 Ethernet controller, the card has a fully integrated 25 Gigabit Ethernet Media Access Control (MAC) and SFI Interface.\u003cbr\u003e\u003cbr\u003eIn addition to managing MAC and PHY Ethernet layer functions, the controller manages PCI Express packet traffic across its transaction, link, and physical\/logical layers. The controller offloads tasks from the host using hardware acceleration, such as TCP\/UDP\/IP checksum calculations and TCP segmentation.\u003cbr\u003e\u003cbr\u003eThis 25 Gigabit Ethernet PCI-Express Network Interface Card is the ideal solution for implementing multiple network segments, mission-critical high-powered networking applications, and environments within high-performance servers.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"text-align: left;\"\u003eKEY FEATURES:\u003c\/h2\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e2x SFP28 ports\u003c\/li\u003e\n\u003cli\u003e1x Intel E810 network controllers\u003c\/li\u003e\n\u003cli\u003e50 Gbps total BW\u003c\/li\u003e\n\u003cli\u003eSupports Direct Attached Copper cable\u003c\/li\u003e\n\u003cli\u003eSupports SFP28-approved 25G and 10G transceivers\u003c\/li\u003e\n\u003cli\u003eLow Profile\u003c\/li\u003e\n\u003cli\u003eBased on Intel E810-CAM1\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHost Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePCI Express GEN4 x8 lanes\u003c\/li\u003e\n\u003cli\u003eSupport PCI Express Base Specification Revision 4.0, 16GT\/s, 8GT\/s, 5GT\/s, or 2.5GT\/s\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLAN and Virtualization Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport for Network Virtualization Offloads including SR-IOV, Geneve, VXLAN and NVGRE\u003c\/li\u003e\n\u003cli\u003eUnified Networking Providing a single wire for LAN and storage: NAS (SMB, NFS) and SAN (iSCSI, FCoE)\u003c\/li\u003e\n\u003cli\u003eRemote SAN boot with data path intelligent offload\u003c\/li\u003e\n\u003cli\u003eVEB (Virtual Ethernet Bridge) \u0026amp; Edge Virtual Bridging \/ 802.1Qbg\u003c\/li\u003e\n\u003cli\u003eVMDq for VMware Netqueue\u003cem\u003e and Microsoft DVMQ\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSR-IOV (Single Root I\/O Virtualization): up to 256 Virtual Functions\u003c\/li\u003e\n\u003cli\u003eiSCSI and PXE boot (legacy and UEFI)\u003c\/li\u003e\n\u003cli\u003eSupport for standard and custom network headers\u003c\/li\u003e\n\u003cli\u003ePartially Programmable Pipeline and Advanced Traffic Steering\u003c\/li\u003e\n\u003cli\u003eIntel® Ethernet Flow Director – 8000 On-Die perfect match filters\u003c\/li\u003e\n\u003cli\u003e1536 queues\/Physical Function (PF), \u0026gt;64 RSS\/PF and 256 VMDq\/PF\u003c\/li\u003e\n\u003cli\u003eData Center Bridging (DCB) up to 8 traffic classes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"text-align: left;\"\u003eSPECIFICATION:\u003c\/h2\u003e\n\u003ctable style=\"width: 100%;\" border=\"1\" cellspacing=\"1\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eSFP28 25 GIGABIT ETHERNET ADAPTER TECHNICAL SPECIFICATIONS:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eSFP28 (Small Form Factor Pluggable) supports:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eSFI interfaces support 25GBase-R PCS and 25 Gigabit PMA to connect with SFP28 to 25GBase-SR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e25GBase-SR SFP28:\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eFiber 25 Gigabit Ethernet, 25GBASE-SR (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e25GBase-SR SFP28:\u003cbr\u003eData Transfer Rate :\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e25.78125 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e25GBase-LR SFP28:\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eFiber 25 Gigabit Ethernet, 25GBASE-LR (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e25GBase-LR SFP28:\u003cbr\u003eData Transfer Rate:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e25.78125 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e25GBase-LR SFP28:\u003cbr\u003eCables and Operating distance Up to:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eSingle-Mode: 10000m at 9um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOPERATING SYSTEMS SUPPORT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOperating system support:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eWindows\u003cbr\u003eLinux\u003cbr\u003eFreeBSD\u003cbr\u003eVMware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eGENERAL TECHNICAL SPECIFICATIONS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eInterface Standard:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003ePCI-Express Base Specification Revision 4.0 (16 GTs)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e(2) SFP28 \/ zSFP+ Cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eBoard Size:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLow profile short add-in card: 145.542mm X 64.389mm (5.730”X 2.535”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLPHL: Low-Profile, Half-Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003ePCI Express Card Type:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eX8 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOn Board Connector Voltage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e+12V +\/-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003ePCI Connector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eGold Finger: X16 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eControllers:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e(1) Intel E810-XXVAM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eHolder:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eMetal Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e0°C – 45°C (32°F – 113°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e-40°C–65°C (-40°F–149°F)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e9.8W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eRegulatory Certifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eCE, FCC Class B, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"text-transform: none;\"\u003eLEDs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eLEDs:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTwo LEDs per port to indicate link status and speed.\u003c\/p\u003e\n\u003cp\u003ePhysical Link \u0026amp; Link Speed LED:\u003cbr\u003eGreen solid – physical link on with 25G Speed\u003cbr\u003eYellow solid – physical link on with 10G Speed\u003cbr\u003eOff – physical link off\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eLogic Link \u0026amp; Activity LED: \u003cbr\u003eGreen solid – logic link up, no activity\u003cbr\u003eGreen blinking – logic link up, activity\u003cbr\u003eOff – logic link off\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eLEDs location:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLEDs are on the PCB, visible via light guides through the metal bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"text-align: left;\"\u003e\n\u003cbr\u003eADDITIONAL INFORMATION:\u003c\/h3\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e* FEATURES AND THROUGHPUT ARE SUBJECT TO HARDWARE AND OPERATING SYSTEM SUPPORT.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: left;\"\u003eWARRANTY AND SUPPORT INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003eNo returns\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eOne year manufacturer's warranty\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eAll specifications are subject to change without notice.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"shop.netgate.com","offers":[{"title":"Default Title","offer_id":43351192731750,"sku":"E13","price":425.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/3173\/6166\/files\/PE425G2i81-25G-angle_1500x1500_4.jpg?v=1759265373"},{"product_id":"2-port-10-gbe-sfp-card","title":"2-Port 10 GbE SFP+ Card","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e10 GIGABIT ETHERNET CARD DUAL PORT FIBER SFP+ NETWORK INTERFACE CARD INTEL\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e X710BM2 BASED\u003c\/h3\u003e\n\u003ch4\u003eHigh Performance, Dual Port 10GbE Ethernet Adapter, Compatible With the Netgate\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e 8300, 1537, and 1541. \u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"des_text\"\u003e\n\u003cp\u003eThis 10 Gigabit Ethernet Dual Port SFP+ Computing PCI Express Network Interface Card offers simple integration into any PCI Express X8 slot to interface with 10Gigabit networks. The performance is optimized so that system I\/O is not the bottleneck in high-performance networking applications. Based on the Intel X710 Ethernet controller, the card has a fully integrated Gigabit Ethernet Media Access Control (MAC) and SFI Interface.\u003c\/p\u003e\n\u003cp\u003eIn addition to managing MAC and PHY Ethernet layer functions, the controller manages PCI Express packet traffic across its transaction, link, and physical\/logical layers. Using hardware acceleration, the controller offloads tasks from the host, such as TCP\/UDP\/IP checksum calculations and TCP segmentation.\u003c\/p\u003e\n\u003cp\u003eThis 10 Gigabit Ethernet PCI-Express Network Interface Card is the ideal solution for implementing multiple network segments, mission-critical high-powered networking applications, and environments within high-performance servers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKEY FEATURES:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports Direct Attached Copper cable\u003c\/li\u003e\n\u003cli\u003eSFP+ approved transceivers\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport for jumbo frame up to 9.5KB\u003c\/li\u003e\n\u003cli\u003eFlow control support\u003c\/li\u003e\n\u003cli\u003ePriority Flow Control (draft IEEE 802.1Qbb)\u003c\/li\u003e\n\u003cli\u003eEnhanced Transmission Selection (draft IEEE802.1az)\u003c\/li\u003e\n\u003cli\u003eStatistics management and RMON\u003c\/li\u003e\n\u003cli\u003e802.1q VLAN support\u003c\/li\u003e\n\u003cli\u003eDCB\/DCB-X support\u003c\/li\u003e\n\u003cli\u003eMessage Signal interrupts (MSI-X)\u003c\/li\u003e\n\u003cli\u003eStorage – Enabling competitive performance with native OS intelligent offload solutions, including NAS, iSCSI and FCoE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHost Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePCI Express GEN3 X8 lanes\u003c\/li\u003e\n\u003cli\u003eSupport PCI Express Base Specification 3.0 (8GT\/sec)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLAN and Virtualization Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Virtualization offloads for VXLAN and NVGRE\u003c\/li\u003e\n\u003cli\u003eUnified Networking Providing a single wire for LAN and storage: NAS (SMB, NFS) and SAN (iSCSI, FCoE)\u003c\/li\u003e\n\u003cli\u003eVirtual Bridging Support – VEPA\/802.1Qbg, BPE\/802.1Qbh\u003c\/li\u003e\n\u003cli\u003ePhysical Functions – Up to 8 per port, up to 16 per device\u003c\/li\u003e\n\u003cli\u003eSupport for 128 Virtual Device Queues (VMDq) per port\u003c\/li\u003e\n\u003cli\u003eHardware Queue Pairs – Up to 1.5K (non-RDMA); up to 256K (RDMA)\u003c\/li\u003e\n\u003cli\u003eVirtualization – Alleviating hypervisor I\/O bottlenecks by providing flow separation for Virtual Machines (VMs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTCP\/IP\/L2 features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReceive Side Scaling (RSS)\u003c\/li\u003e\n\u003cli\u003eLarge Send Offload (LSO)\u003c\/li\u003e\n\u003cli\u003eTCP\/UDP\/IP\/SCTP Checksum Offload\u003c\/li\u003e\n\u003cli\u003eIPV4, IPV6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSPECIFICATION:\u003c\/h3\u003e\n\u003ctable border=\"1\" cellspacing=\"1\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eSFP+ 10GIGABIT ETHERNET TECHNICAL SPECIFICATIONS ADAPTERS:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP+ (Small Form Factor Pluggable) supports:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFI interfaces supports 10GBase-R PCS and 10 Gigabit PMA in order to connect with SFP+ to 10GBase-SR \/ \/ 1000Base-SX \/ 10GBase-LR and SFP+ Direct Attach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.5um, 160MHz\/Km 26m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 33m\u003cbr\u003e50um, 400MHz\/Km 66m\u003cbr\u003e50um, (OM2)500 MHz\/Km 82m\u003cbr\u003e50um, (OM3)2000MHz\/Km 300m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10GBase-LR SFP+:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eFiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-LR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-LR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode: 10000m at 9um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GSFP+Cu :\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper 10Gigabit Ethernet, 10GSFP+Cu (Direct Attach)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Gigabit Ethernet, 1000Base-SX (850nM LAN PHY)\u003cbr\u003eFiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd \/ 1.25GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10000Base-SX:\u003c\/strong\u003e\u003cbr\u003e62.5um, 160MHz\/Km 220m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 275m\u003cbr\u003e50um, 400MHz\/Km 500m\u003cbr\u003e50um, (OM2)500 MHz\/Km 550m\u003cbr\u003e50um, (OM3)2000MHz\/Km \u0026gt;550m\u003cbr\u003e\u003cstrong\u003e10GBase-SR:\u003c\/strong\u003e\u003cbr\u003e62.5um, 160MHz\/Km 26m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 33m\u003cbr\u003e50um, 400MHz\/Km 66m\u003cbr\u003e50um, (OM2)500 MHz\/Km 82m\u003cbr\u003e50um, (OM3)2000MHz\/Km 300m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Gigabit Ethernet, 1000Base-LX (1310nM LAN PHY)\u003cbr\u003eFiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd \/ 1.25GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10000Base-LX:\u003c\/strong\u003e\u003cbr\u003eSingle-Mode: 5000m at 9um\u003cbr\u003e\u003cstrong\u003e10GBase-LR:\u003c\/strong\u003e\u003cbr\u003eSingle-Mode: 10000m at 9um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-T SFP:\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000BASE-T Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOPERATING SYSTEMS SUPPORT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating system support:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows\u003cbr\u003eLinux\u003cbr\u003eFreeBSD\u003cbr\u003eVMware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eGENERAL TECHNICAL SPECIFICATIONS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Standard:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI-Express Base Specification Revision 3.0 ( 8 GTs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoard Size:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow profile short add-in card: 145.542mm X 64.389mm (5.730”X 2.535”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCI Express Card Type:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX8 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn Board Connector Voltage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12V +\/-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCI Connector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX8 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControllers:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntel X710BM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHolder:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C – 45°C (32°F – 113°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C–65°C (-40°F–149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Certifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCC 47CFR Part 15:2013, Subpart B Class B\u003cbr\u003eConducted emissions\u003cbr\u003eRadiated emissions\u003cbr\u003eEN 55022: 2010, Class B\u003cbr\u003eConducted disturbance at mains terminals\u003cbr\u003eConducted disturbance at telecommunication port\u003cbr\u003eRadiated disturbance\u003cbr\u003eEN 61000-3-2: 2006+A1(09)+A2(09)\u003cbr\u003eHarmonic current emissions\u003cbr\u003eEN 61000-3-3: 2008\u003cbr\u003eVoltage fluctuations and flicker\u003cbr\u003eEN 55024: 2010\u003cbr\u003eImmunity to electrostatic discharge (ESD)\u003cbr\u003eRadiated immunity to radio frequency electromagnetic field\u003cbr\u003eConducted immunity to electrical fast transients \/ bursts (EFT\/ B)\u003cbr\u003eConducted immunity to voltage surges\u003cbr\u003eConducted immunity to disturbances induced by radio frequency field\u003cbr\u003eConducted immunity to voltage dips and short interruptions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eLEDS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLEDs:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(2) LEDs per port\u003cbr\u003eLink Speed:\u003cbr\u003eTurns on Green 10G Link.\u003cbr\u003eTurn on Yellow on 1G Link\u003cbr\u003eLink\/Act :\u003cbr\u003eTurns on link (Green),\u003cbr\u003eBlinks on activity (Green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLEDs location:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLEDs are located on the PCB, visible via holes in the metal bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(2) SFP+ cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cbr\u003eADDITIONAL INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIf you are utilizing this card in the Netgate 1537 or 1541, you MUST add an additional 40mm case fan with at least 200 lf\/m.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePLEASE CONTACT US IF YOU ARE ADDING THIS CARD TO THE Netgate 1541 OR 1537 SYSTEM FOR ADDITIONAL REQUIRED COMPONENTS.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e* FEATURES AND THROUGHPUT ARE SUBJECT TO HARDWARE AND OPERATING SYSTEM SUPPORT.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWARRANTY AND SUPPORT INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo returns\u003c\/li\u003e\n\u003cli\u003e1 year manufacturers warranty\u003c\/li\u003e\n\u003cli\u003eAll Specifications subject to change without notice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"shop.netgate.com","offers":[{"title":"Default Title","offer_id":43351211081830,"sku":"E09","price":299.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/3173\/6166\/files\/products_IntelX710BM2-2port_angle.jpg?v=1759265374"},{"product_id":"4-port-10-gbe-sfp-card","title":"4-Port 10 GbE SFP+ Card","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e10 GIGABIT ETHERNET CARD QUAD PORT FIBER SFP+ NETWORK INTERFACE CARD INTEL\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e X710BM2 BASED\u003c\/h3\u003e\n\u003ch4\u003eHigh Performance, Quad Port 10GbE Ethernet Adapter, Compatible With the Netgate\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e 8300, 1537, and 1541.\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"des_text\"\u003e\n\u003cp\u003eThis 10 Gigabit Ethernet Quad Port SFP+ Computing PCI Express Network Interface Card offers simple integration into any PCI Express X8 slot to interface with 10Gigabit networks. The performance is optimized so that system I\/O is not the bottleneck in high-performance networking applications. Based on the Intel X710 Ethernet controller, the card has a fully integrated Gigabit Ethernet Media Access Control (MAC) and SFI Interface.\u003c\/p\u003e\n\u003cp\u003eIn addition to managing MAC and PHY Ethernet layer functions, the controller manages PCI Express packet traffic across its transaction, link, and physical\/logical layers. Using hardware acceleration, the controller offloads tasks from the host, such as TCP\/UDP\/IP checksum calculations and TCP segmentation.\u003c\/p\u003e\n\u003cp\u003eThis 10 Gigabit Ethernet PCI-Express Network Interface Card is the ideal solution for implementing multiple network segments, mission-critical high-powered networking applications, and environments within high-performance servers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKEY FEATURES:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports Direct Attached Copper cable\u003c\/li\u003e\n\u003cli\u003eSFP+ approved transceivers\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport for jumbo frame up to 9.5KB\u003c\/li\u003e\n\u003cli\u003eFlow control support\u003c\/li\u003e\n\u003cli\u003ePriority Flow Control (draft IEEE 802.1Qbb)\u003c\/li\u003e\n\u003cli\u003eEnhanced Transmission Selection (draft IEEE802.1az)\u003c\/li\u003e\n\u003cli\u003eStatistics management and RMON\u003c\/li\u003e\n\u003cli\u003e802.1q VLAN support\u003c\/li\u003e\n\u003cli\u003eDCB\/DCB-X support\u003c\/li\u003e\n\u003cli\u003eMessage Signal interrupts (MSI-X)\u003c\/li\u003e\n\u003cli\u003eStorage – Enabling competitive performance with native OS intelligent offload solutions, including NAS, iSCSI and FCoE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHost Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePCI Express GEN3 X8 lanes\u003c\/li\u003e\n\u003cli\u003eSupport PCI Express Base Specification 3.0 (8GT\/sec)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLAN and Virtualization Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Virtualization offloads for VXLAN and NVGRE\u003c\/li\u003e\n\u003cli\u003eUnified Networking Providing a single wire for LAN and storage: NAS (SMB, NFS) and SAN (iSCSI, FCoE)\u003c\/li\u003e\n\u003cli\u003eVirtual Bridging Support – VEPA\/802.1Qbg, BPE\/802.1Qbh\u003c\/li\u003e\n\u003cli\u003ePhysical Functions – Up to 8 per port, up to 16 per device\u003c\/li\u003e\n\u003cli\u003eSupport for 128 Virtual Device Queues (VMDq) per port\u003c\/li\u003e\n\u003cli\u003eHardware Queue Pairs – Up to 1.5K (non-RDMA); up to 256K (RDMA)\u003c\/li\u003e\n\u003cli\u003eVirtualization – Alleviating hypervisor I\/O bottlenecks by providing flow separation for Virtual Machines (VMs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTCP\/IP\/L2 features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReceive Side Scaling (RSS)\u003c\/li\u003e\n\u003cli\u003eLarge Send Offload (LSO)\u003c\/li\u003e\n\u003cli\u003eTCP\/UDP\/IP\/SCTP Checksum Offload\u003c\/li\u003e\n\u003cli\u003eIPV4, IPV6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSPECIFICATION:\u003c\/h3\u003e\n\u003ctable border=\"1\" cellspacing=\"1\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eSFP+ 10GIGABIT ETHERNET TECHNICAL SPECIFICATIONS ADAPTERS:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP+ (Small Form Factor Pluggable) supports:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFI interfaces supports 10GBase-R PCS and 10 Gigabit PMA in order to connect with SFP+ to 10GBase-SR \/ \/ 1000Base-SX \/ 10GBase-LR and SFP+ Direct Attach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.5um, 160MHz\/Km 26m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 33m\u003cbr\u003e50um, 400MHz\/Km 66m\u003cbr\u003e50um, (OM2)500 MHz\/Km 82m\u003cbr\u003e50um, (OM3)2000MHz\/Km 300m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10GBase-LR SFP+:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eFiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-LR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-LR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode: 10000m at 9um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GSFP+Cu :\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper 10Gigabit Ethernet, 10GSFP+Cu (Direct Attach)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Gigabit Ethernet, 1000Base-SX (850nM LAN PHY)\u003cbr\u003eFiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd \/ 1.25GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10000Base-SX:\u003c\/strong\u003e\u003cbr\u003e62.5um, 160MHz\/Km 220m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 275m\u003cbr\u003e50um, 400MHz\/Km 500m\u003cbr\u003e50um, (OM2)500 MHz\/Km 550m\u003cbr\u003e50um, (OM3)2000MHz\/Km \u0026gt;550m\u003cbr\u003e\u003cstrong\u003e10GBase-SR:\u003c\/strong\u003e\u003cbr\u003e62.5um, 160MHz\/Km 26m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 33m\u003cbr\u003e50um, 400MHz\/Km 66m\u003cbr\u003e50um, (OM2)500 MHz\/Km 82m\u003cbr\u003e50um, (OM3)2000MHz\/Km 300m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Gigabit Ethernet, 1000Base-LX (1310nM LAN PHY)\u003cbr\u003eFiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd \/ 1.25GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10000Base-LX:\u003c\/strong\u003e\u003cbr\u003eSingle-Mode: 5000m at 9um\u003cbr\u003e\u003cstrong\u003e10GBase-LR:\u003c\/strong\u003e\u003cbr\u003eSingle-Mode: 10000m at 9um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-T SFP:\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000BASE-T Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOPERATING SYSTEMS SUPPORT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating system support:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows\u003cbr\u003eLinux\u003cbr\u003eFreeBSD\u003cbr\u003eVMware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eGENERAL TECHNICAL SPECIFICATIONS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Standard:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI-Express Base Specification Revision 3.0 ( 8 GTs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoard Size:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow profile short add-in card: 145.542mm X 64.389mm (5.730”X 2.535”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCI Express Card Type:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX8 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn Board Connector Voltage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12V +\/-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCI Connector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX8 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControllers:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntel X710BM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHolder:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C – 45°C (32°F – 113°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C–65°C (-40°F–149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Certifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCC 47CFR Part 15:2013, Subpart B Class B\u003cbr\u003eConducted emissions\u003cbr\u003eRadiated emissions\u003cbr\u003eEN 55022: 2010, Class B\u003cbr\u003eConducted disturbance at mains terminals\u003cbr\u003eConducted disturbance at telecommunication port\u003cbr\u003eRadiated disturbance\u003cbr\u003eEN 61000-3-2: 2006+A1(09)+A2(09)\u003cbr\u003eHarmonic current emissions\u003cbr\u003eEN 61000-3-3: 2008\u003cbr\u003eVoltage fluctuations and flicker\u003cbr\u003eEN 55024: 2010\u003cbr\u003eImmunity to electrostatic discharge (ESD)\u003cbr\u003eRadiated immunity to radio frequency electromagnetic field\u003cbr\u003eConducted immunity to electrical fast transients \/ bursts (EFT\/ B)\u003cbr\u003eConducted immunity to voltage surges\u003cbr\u003eConducted immunity to disturbances induced by radio frequency field\u003cbr\u003eConducted immunity to voltage dips and short interruptions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eLEDS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLEDs:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(2) LEDs per port\u003cbr\u003eLink Speed:\u003cbr\u003eTurns on Green 10G Link.\u003cbr\u003eTurn on Yellow on 1G Link\u003cbr\u003eLink\/Act :\u003cbr\u003eTurns on link (Green),\u003cbr\u003eBlinks on activity (Green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLEDs location:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLEDs are located on the PCB, visible via holes in the metal bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(4) SFP+ cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cbr\u003eADDITIONAL INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIf you are utilizing this card in the Netgate 1537 or 1541, you MUST add an additional 40mm case fan with at least 200 lf\/m.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePLEASE CONTACT US IF YOU ARE ADDING THIS CARD TO THE Netgate 1541 OR 1537 SYSTEM FOR ADDITIONAL REQUIRED COMPONENTS.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e* FEATURES AND THROUGHPUT ARE SUBJECT TO HARDWARE AND OPERATING SYSTEM SUPPORT.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWARRANTY AND SUPPORT INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo returns\u003c\/li\u003e\n\u003cli\u003e1 year manufacturers warranty\u003c\/li\u003e\n\u003cli\u003eAll Specifications subject to change without notice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"shop.netgate.com","offers":[{"title":"Default Title","offer_id":43351240147046,"sku":"E11","price":499.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/3173\/6166\/files\/products_IntelX710BM2-4port_angle_1_360x_bbfa617c-1589-4d35-bf1f-4164e834e324.jpg?v=1759265385"},{"product_id":"intel-e810-ethernet-network-interface-card-25g-dual-port-sfp28-pcie-4-0-x16-50-gb-total-bandwidth","title":"Intel E810 Ethernet Network Interface Card, 25G Dual Port SFP28, PCIe 4.0 x16, 50 GB Total Bandwidth","description":"\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003e25 GIGABIT ETHERNET LOW PROFILE CARD DUAL-PORT FIBER \u0026amp; DAC SFP28 NETWORK INTERFACE CARD INTEL\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e E810 BASED \u003c\/h2\u003e\n\u003ch4 style=\"text-align: left;\"\u003eHIGH-PERFORMANCE, DUAL-PORT SFP28 25\/10\/1 GIGABIT ETHERNET PCI EXPRESS SERVER ADAPTER\u003c\/h4\u003e\n\u003cp style=\"text-align: left;\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv class=\"des_text\"\u003e\n\u003cp\u003eThis 25 Gigabit Ethernet Dual-Port SFP28 Computing PCI Express Network Interface Card offers simple integration into any PCI Express X16 slot to interface with 25 Gigabit networks. The performance is optimized so that system I\/O is not the bottleneck in high-performance networking applications. Based on the Intel E810 XXVAM2 Ethernet controller, the card has a fully integrated 25 Gigabit Ethernet Media Access Control (MAC) and SFI Interface.\u003cbr\u003e\u003cbr\u003eIn addition to managing MAC and PHY Ethernet layer functions, the controller manages PCI Express packet traffic across its transaction, link, and physical\/logical layers. The controller offloads tasks from the host using hardware acceleration, such as TCP\/UDP\/IP checksum calculations and TCP segmentation.\u003cbr\u003e\u003cbr\u003eThis 25 Gigabit Ethernet PCI-Express Network Interface Card is the ideal solution for implementing multiple network segments, mission-critical high-powered networking applications, and environments within high-performance servers.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"text-align: left;\"\u003eKEY FEATURES:\u003c\/h2\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e2x SFP28 ports\u003c\/li\u003e\n\u003cli\u003e1x Intel E810 network controllers\u003c\/li\u003e\n\u003cli\u003e50 Gbps total BW\u003c\/li\u003e\n\u003cli\u003eSupports Direct Attached Copper cable\u003c\/li\u003e\n\u003cli\u003eSupports SFP28-approved 25G and 10G transceivers\u003c\/li\u003e\n\u003cli\u003eLow Profile\u003c\/li\u003e\n\u003cli\u003eBased on Intel E810-CAM2\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHost Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePCI Express GEN4 x8 lanes\u003c\/li\u003e\n\u003cli\u003eSupport PCI Express Base Specification Revision 4.0, 16GT\/s, 8GT\/s, 5GT\/s, or 2.5GT\/s\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLAN and Virtualization Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport for Network Virtualization Offloads including SR-IOV, Geneve, VXLAN and NVGRE\u003c\/li\u003e\n\u003cli\u003eUnified Networking Providing a single wire for LAN and storage: NAS (SMB, NFS) and SAN (iSCSI, FCoE)\u003c\/li\u003e\n\u003cli\u003eRemote SAN boot with data path intelligent offload\u003c\/li\u003e\n\u003cli\u003eVEB (Virtual Ethernet Bridge) \u0026amp; Edge Virtual Bridging \/ 802.1Qbg\u003c\/li\u003e\n\u003cli\u003eVMDq for VMware Netqueue\u003cem\u003e and Microsoft DVMQ\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSR-IOV (Single Root I\/O Virtualization): up to 256 Virtual Functions\u003c\/li\u003e\n\u003cli\u003eiSCSI and PXE boot (legacy and UEFI)\u003c\/li\u003e\n\u003cli\u003eSupport for standard and custom network headers\u003c\/li\u003e\n\u003cli\u003ePartially Programmable Pipeline and Advanced Traffic Steering\u003c\/li\u003e\n\u003cli\u003eIntel® Ethernet Flow Director – 8000 On-Die perfect match filters\u003c\/li\u003e\n\u003cli\u003e1536 queues\/Physical Function (PF), \u0026gt;64 RSS\/PF and 256 VMDq\/PF\u003c\/li\u003e\n\u003cli\u003eData Center Bridging (DCB) up to 8 traffic classes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"text-align: left;\"\u003eSPECIFICATION:\u003c\/h2\u003e\n\u003ctable style=\"width: 100%;\" border=\"1\" cellspacing=\"1\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eSFP28 25 GIGABIT ETHERNET ADAPTER TECHNICAL SPECIFICATIONS:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eSFP28 (Small Form Factor Pluggable) supports:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eSFI interfaces support 25GBase-R PCS and 25 Gigabit PMA to connect with SFP28 to 25GBase-SR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e25GBase-SR SFP28:\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eFiber 25 Gigabit Ethernet, 25GBASE-SR (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e25GBase-SR SFP28:\u003cbr\u003eData Transfer Rate :\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e25.78125 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e25GBase-LR SFP28:\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eFiber 25 Gigabit Ethernet, 25GBASE-LR (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e25GBase-LR SFP28:\u003cbr\u003eData Transfer Rate:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e25.78125 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e25GBase-LR SFP28:\u003cbr\u003eCables and Operating distance Up to:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eSingle-Mode: 10000m at 9um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOPERATING SYSTEMS SUPPORT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOperating system support:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eWindows\u003cbr\u003eLinux\u003cbr\u003eFreeBSD\u003cbr\u003eVMware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eGENERAL TECHNICAL SPECIFICATIONS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eInterface Standard:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003ePCI-Express Base Specification Revision 4.0 (16 GTs)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e(2) SFP28 \/ zSFP+ Cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eBoard Size:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLow profile short add-in card: 145.542mm X 64.389mm (5.730”X 2.535”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLPHL: Low-Profile, Half-Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003ePCI Express Card Type:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eX8 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOn Board Connector Voltage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e+12V +\/-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003ePCI Connector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eGold Finger: X16 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eControllers:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e(1) Intel E810-XXVAM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eHolder:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eMetal Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e0°C – 45°C (32°F – 113°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e-40°C–65°C (-40°F–149°F)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e9.8W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eRegulatory Certifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eCE, FCC Class B, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"text-transform: none;\"\u003eLEDs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eLEDs:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTwo LEDs per port to indicate link status and speed.\u003c\/p\u003e\n\u003cp\u003ePhysical Link \u0026amp; Link Speed LED:\u003cbr\u003eGreen solid – physical link on with 25G Speed\u003cbr\u003eYellow solid – physical link on with 10G Speed\u003cbr\u003eOff – physical link off\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eLogic Link \u0026amp; Activity LED: \u003cbr\u003eGreen solid – logic link up, no activity\u003cbr\u003eGreen blinking – logic link up, activity\u003cbr\u003eOff – logic link off\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eLEDs location:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLEDs are on the PCB, visible via light guides through the metal bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"text-align: left;\"\u003e\n\u003cbr\u003eADDITIONAL INFORMATION:\u003c\/h3\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e* FEATURES AND THROUGHPUT ARE SUBJECT TO HARDWARE AND OPERATING SYSTEM SUPPORT.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: left;\"\u003eWARRANTY AND SUPPORT INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003eNo returns\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eOne year manufacturer's warranty\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eAll specifications are subject to change without notice.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"shop.netgate.com","offers":[{"title":"Default Title","offer_id":45664933544038,"sku":"E13","price":425.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/3173\/6166\/files\/PE425G2i81-25G-angle_1500x1500_4_d619fa01-4954-4d6c-a808-9d174cfbd501.jpg?v=1782258156"},{"product_id":"intel-x810-ethernet-network-interface-card-100g-dual-port-qsfp28-pcie-4-0-x16-100-gb-total-bandwidth","title":"Intel E810 Ethernet Network Interface Card, 100G Dual Port QSFP28, PCIe 4.0 x16, 100 GB Total Bandwidth","description":"\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003e100 GIGABIT ETHERNET LOW PROFILE CARD DUAL-PORT FIBER \u0026amp; DAC QSFP28 NETWORK INTERFACE CARD INTEL\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e E810-CAM2 BASED \u003c\/h2\u003e\n\u003ch4 style=\"text-align: left;\"\u003eHIGH-PERFORMANCE, DUAL-PORT 100 GBE ETHERNET ADAPTER, COMPATIBLE WITH THE NETGATE\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e 8300\u003c\/h4\u003e\n\u003cp style=\"text-align: left;\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv class=\"des_text\"\u003e\n\u003cp\u003eThis 100 Gigabit Ethernet Dual-Port QSFP28 Computing PCI Express Network Interface Card offers simple integration into any PCI Express x16 slot to interface with 100 Gigabit networks. The performance is optimized so that system I\/O is not the bottleneck in high-performance networking applications. Based on the Intel E810-CAM2 Ethernet controller, the card has two fully integrated 100G Ethernet Ports, enhanced programmable packet processing pipeline, virtualization (Enhanced SR-IOV support with up to 256 VFs, backward compatibility VF driver support), new features for the communications market (fine-grained scheduler, transmit head drop support, adjustment of credits according to different headers, enhanced QoS, enhanced burst control) and RDMA (iWARP and RoCEv2).\u003cbr\u003e\u003cbr\u003eThis 100 Gigabit Ethernet PCI-Express Network Interface Card is the ideal solution for implementing multiple network segments, mission-critical high-powered networking applications, and environments within high-performance servers.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"text-align: left;\"\u003eKEY FEATURES:\u003c\/h2\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e2x QSFP28 ports\u003c\/li\u003e\n\u003cli\u003e100 Gbps total BW\u003c\/li\u003e\n\u003cli\u003eSERDES capable of 25G NRZ\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAuto-negotiation with auto-detect.\u003c\/li\u003e\n\u003cli\u003eIEEE1588 Precision Time Protocol\u003c\/li\u003e\n\u003cli\u003eSupports Direct Attached Copper cable\u003c\/li\u003e\n\u003cli\u003eSupports QSFP28 100G transceivers\u003c\/li\u003e\n\u003cli\u003eBased on Intel E810-CAM2\u003c\/li\u003e\n\u003cli\u003eLow Profile\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHost Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePCIe x16 lanes from\/to host via gold fingers of edge card\u003c\/li\u003e\n\u003cli\u003eSupport PCI Express Base Specification Revision 4.0, 16GT\/s, 8GT\/s, 5GT\/s or 2.5GT\/s Compliance with PCIe spec 4.0 currently at draft 0.9\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLAN and Virtualization Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100 Gbps throughput (each of Tx and Rx)\u003c\/li\u003e\n\u003cli\u003eParses up to 504B from packet header\u003c\/li\u003e\n\u003cli\u003e768 switch ports (VSIs)\u003c\/li\u003e\n\u003cli\u003eProgrammable forwarding rules\u003c\/li\u003e\n\u003cli\u003eVirtualization\n\u003cul\u003e\n\u003cli\u003eHost virtualization via VMQ and SR-IOV\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003eSupport for offloads including Geneve, VxLAN and NVGRE\u003c\/li\u003e\n\u003cli\u003e256 SR-IOV Virtual Functions\u003c\/li\u003e\n\u003cli\u003eStateless offloads for tunneled packets (network virtualization support)\u003c\/li\u003e\n\u003cli\u003eMalicious VF protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eRDMA\n\u003cul\u003e\n\u003cli\u003eiWARP and RoCE v2\u003c\/li\u003e\n\u003cli\u003e256K Queue Pairs (QPs)\u003c\/li\u003e\n\u003cli\u003eSend Queue Push Mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eQoS\n\u003cul\u003e\n\u003cli\u003eWFQ Transmit scheduler with 9 programmable layers\u003c\/li\u003e\n\u003cli\u003ePipeline sharing and starvation avoidance\u003c\/li\u003e\n\u003cli\u003eUp to 32 Congestion Domains in the Tx and Rx paths\u003c\/li\u003e\n\u003cli\u003eQoS via 802.1p PCP or Differentiated services DSCP value\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRx Packet buffer supports at least 3 no-drop flow control events, shared among ports\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"text-align: left;\"\u003eSPECIFICATION:\u003c\/h2\u003e\n\u003ctable style=\"width: 100%;\" border=\"1\" cellspacing=\"1\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eQSFP28 100 GIGABIT ETHERNET ADAPTER TECHNICAL SPECIFICATIONS:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eQSFP28 (Small Form Factor Pluggable) supports:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e100GBASE: CAUI-4 interfaces conforming to IEEE 802.3bm and IEEE 802.3bj standards, to support 100GBase-SR4, 100GBase-LR4 and 100GBase-CR4 interfaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-SR4\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eFiber 100 Gigabit Ethernet, 100GBASE-SR4 (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-SR4\u003cbr\u003eData Transfer Rate:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e103.125 GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-SR4\u003cbr\u003eCable type and Operating distance up to:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eMultimode fiber: 62.5um, (OM4) 100m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-LR4\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eFiber 100 Gigabit Ethernet, 100GBASE-LR4 (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-LR4 QSFP28\u003cbr\u003eData Transfer Rate:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e103.1 GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003e100GBase-LR4 QSFP28\u003cbr\u003eCables and Operating distance Up to:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eSingle-Mode: 10km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOPERATING SYSTEMS SUPPORT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOperating system support:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eWindows\u003cbr\u003eLinux\u003cbr\u003eFreeBSD\u003cbr\u003eVMware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eGENERAL TECHNICAL SPECIFICATIONS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eInterface Standard:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003ePCI-Express Base Specification Revision 4.0 ( 16 GTs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e(2) QSFP28 Cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eBoard Size:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLow profile short add-in card 167.64mm X 68.91mm (6.60”X 2.713”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLPHL, Low-Profile, Half-Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003ePCI Express Card Type:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eX16 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOn Board Connector Voltage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e+12V +\/-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003ePCI Connector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eGold Finger: X16 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eControllers:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eIntel E810-CAM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eHolder:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eMetal Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e0°C – 45°C (32°F – 113°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e-40°C–65°C (-40°F–149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e0%–90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eRegulatory Certifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eCE, FCC Class B, ROHS, TAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 99.8162%;\" colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"text-transform: none;\"\u003eLEDs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eLEDs:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003e\n\u003cp\u003eTwo LEDs per port to indicate link status and speed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e100\/25\/10 Gbps link speed LED:\u003cbr\u003eLED on = link is up\u003cbr\u003e100Gbps (Green)\u003cbr\u003e25G\/10Gbps (Yellow)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eLink\/Act 100\/25\/10 Gbps LED (Green):\u003cbr\u003eSolid = link\u003cbr\u003eBlink = activity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0662%;\"\u003e\u003cstrong\u003eLEDs location:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.75%;\"\u003eLEDs are on the PCB, visible via light guides through the metal bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"text-align: left;\"\u003e\n\u003cbr\u003eADDITIONAL INFORMATION:\u003c\/h3\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli\u003e\u003cstrong\u003eWorks with the Netgate 8300 and other systems that support PCI-e 4.0 low profile short add-in cards.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUse with the Netgate 8300 with TNSR for high speed network transfer applications.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e* Features and throughput are subject to hardware and operating system support. \u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: left;\"\u003eWARRANTY AND SUPPORT INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003eNo returns\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eOne year manufacturer's warranty\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eAll specifications are subject to change without notice.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"shop.netgate.com","offers":[{"title":"Default Title","offer_id":45664933937254,"sku":"E14","price":850.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/3173\/6166\/files\/P4CG2I81_angle_1500x1500_2_6f3f5654-247c-4e8b-a402-fb02ac620421.jpg?v=1782258157"},{"product_id":"intel-x710-ethernet-network-interface-card-10g-quad-port-sfp-pcie-3-0-x8","title":"Intel X710 Ethernet Network Interface Card, 10G Quad Port SFP+, PCIe 3.0 x8","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e10 GIGABIT ETHERNET CARD QUAD PORT FIBER SFP+ NETWORK INTERFACE CARD INTEL\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e X710BM2 BASED\u003c\/h3\u003e\n\u003ch4\u003eHigh Performance, Quad Port 10GbE Ethernet Adapter, Compatible With the Netgate\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e 8300, 1537, and 1541.\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"des_text\"\u003e\n\u003cp\u003eThis 10 Gigabit Ethernet Quad Port SFP+ Computing PCI Express Network Interface Card offers simple integration into any PCI Express X8 slot to interface with 10Gigabit networks. The performance is optimized so that system I\/O is not the bottleneck in high-performance networking applications. Based on the Intel X710 Ethernet controller, the card has a fully integrated Gigabit Ethernet Media Access Control (MAC) and SFI Interface.\u003c\/p\u003e\n\u003cp\u003eIn addition to managing MAC and PHY Ethernet layer functions, the controller manages PCI Express packet traffic across its transaction, link, and physical\/logical layers. Using hardware acceleration, the controller offloads tasks from the host, such as TCP\/UDP\/IP checksum calculations and TCP segmentation.\u003c\/p\u003e\n\u003cp\u003eThis 10 Gigabit Ethernet PCI-Express Network Interface Card is the ideal solution for implementing multiple network segments, mission-critical high-powered networking applications, and environments within high-performance servers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKEY FEATURES:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports Direct Attached Copper cable\u003c\/li\u003e\n\u003cli\u003eSFP+ approved transceivers\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport for jumbo frame up to 9.5KB\u003c\/li\u003e\n\u003cli\u003eFlow control support\u003c\/li\u003e\n\u003cli\u003ePriority Flow Control (draft IEEE 802.1Qbb)\u003c\/li\u003e\n\u003cli\u003eEnhanced Transmission Selection (draft IEEE802.1az)\u003c\/li\u003e\n\u003cli\u003eStatistics management and RMON\u003c\/li\u003e\n\u003cli\u003e802.1q VLAN support\u003c\/li\u003e\n\u003cli\u003eDCB\/DCB-X support\u003c\/li\u003e\n\u003cli\u003eMessage Signal interrupts (MSI-X)\u003c\/li\u003e\n\u003cli\u003eStorage – Enabling competitive performance with native OS intelligent offload solutions, including NAS, iSCSI and FCoE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHost Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePCI Express GEN3 X8 lanes\u003c\/li\u003e\n\u003cli\u003eSupport PCI Express Base Specification 3.0 (8GT\/sec)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLAN and Virtualization Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Virtualization offloads for VXLAN and NVGRE\u003c\/li\u003e\n\u003cli\u003eUnified Networking Providing a single wire for LAN and storage: NAS (SMB, NFS) and SAN (iSCSI, FCoE)\u003c\/li\u003e\n\u003cli\u003eVirtual Bridging Support – VEPA\/802.1Qbg, BPE\/802.1Qbh\u003c\/li\u003e\n\u003cli\u003ePhysical Functions – Up to 8 per port, up to 16 per device\u003c\/li\u003e\n\u003cli\u003eSupport for 128 Virtual Device Queues (VMDq) per port\u003c\/li\u003e\n\u003cli\u003eHardware Queue Pairs – Up to 1.5K (non-RDMA); up to 256K (RDMA)\u003c\/li\u003e\n\u003cli\u003eVirtualization – Alleviating hypervisor I\/O bottlenecks by providing flow separation for Virtual Machines (VMs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTCP\/IP\/L2 features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReceive Side Scaling (RSS)\u003c\/li\u003e\n\u003cli\u003eLarge Send Offload (LSO)\u003c\/li\u003e\n\u003cli\u003eTCP\/UDP\/IP\/SCTP Checksum Offload\u003c\/li\u003e\n\u003cli\u003eIPV4, IPV6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSPECIFICATION:\u003c\/h3\u003e\n\u003ctable border=\"1\" cellspacing=\"1\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eSFP+ 10GIGABIT ETHERNET TECHNICAL SPECIFICATIONS ADAPTERS:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP+ (Small Form Factor Pluggable) supports:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFI interfaces supports 10GBase-R PCS and 10 Gigabit PMA in order to connect with SFP+ to 10GBase-SR \/ \/ 1000Base-SX \/ 10GBase-LR and SFP+ Direct Attach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.5um, 160MHz\/Km 26m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 33m\u003cbr\u003e50um, 400MHz\/Km 66m\u003cbr\u003e50um, (OM2)500 MHz\/Km 82m\u003cbr\u003e50um, (OM3)2000MHz\/Km 300m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10GBase-LR SFP+:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eFiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-LR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-LR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode: 10000m at 9um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GSFP+Cu :\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper 10Gigabit Ethernet, 10GSFP+Cu (Direct Attach)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Gigabit Ethernet, 1000Base-SX (850nM LAN PHY)\u003cbr\u003eFiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd \/ 1.25GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10000Base-SX:\u003c\/strong\u003e\u003cbr\u003e62.5um, 160MHz\/Km 220m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 275m\u003cbr\u003e50um, 400MHz\/Km 500m\u003cbr\u003e50um, (OM2)500 MHz\/Km 550m\u003cbr\u003e50um, (OM3)2000MHz\/Km \u0026gt;550m\u003cbr\u003e\u003cstrong\u003e10GBase-SR:\u003c\/strong\u003e\u003cbr\u003e62.5um, 160MHz\/Km 26m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 33m\u003cbr\u003e50um, 400MHz\/Km 66m\u003cbr\u003e50um, (OM2)500 MHz\/Km 82m\u003cbr\u003e50um, (OM3)2000MHz\/Km 300m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Gigabit Ethernet, 1000Base-LX (1310nM LAN PHY)\u003cbr\u003eFiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd \/ 1.25GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10000Base-LX:\u003c\/strong\u003e\u003cbr\u003eSingle-Mode: 5000m at 9um\u003cbr\u003e\u003cstrong\u003e10GBase-LR:\u003c\/strong\u003e\u003cbr\u003eSingle-Mode: 10000m at 9um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-T SFP:\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000BASE-T Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOPERATING SYSTEMS SUPPORT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating system support:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows\u003cbr\u003eLinux\u003cbr\u003eFreeBSD\u003cbr\u003eVMware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eGENERAL TECHNICAL SPECIFICATIONS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Standard:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI-Express Base Specification Revision 3.0 ( 8 GTs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoard Size:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow profile short add-in card: 145.542mm X 64.389mm (5.730”X 2.535”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCI Express Card Type:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX8 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn Board Connector Voltage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12V +\/-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCI Connector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX8 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControllers:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntel X710BM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHolder:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C – 45°C (32°F – 113°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C–65°C (-40°F–149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Certifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCC 47CFR Part 15:2013, Subpart B Class B\u003cbr\u003eConducted emissions\u003cbr\u003eRadiated emissions\u003cbr\u003eEN 55022: 2010, Class B\u003cbr\u003eConducted disturbance at mains terminals\u003cbr\u003eConducted disturbance at telecommunication port\u003cbr\u003eRadiated disturbance\u003cbr\u003eEN 61000-3-2: 2006+A1(09)+A2(09)\u003cbr\u003eHarmonic current emissions\u003cbr\u003eEN 61000-3-3: 2008\u003cbr\u003eVoltage fluctuations and flicker\u003cbr\u003eEN 55024: 2010\u003cbr\u003eImmunity to electrostatic discharge (ESD)\u003cbr\u003eRadiated immunity to radio frequency electromagnetic field\u003cbr\u003eConducted immunity to electrical fast transients \/ bursts (EFT\/ B)\u003cbr\u003eConducted immunity to voltage surges\u003cbr\u003eConducted immunity to disturbances induced by radio frequency field\u003cbr\u003eConducted immunity to voltage dips and short interruptions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eLEDS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLEDs:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(2) LEDs per port\u003cbr\u003eLink Speed:\u003cbr\u003eTurns on Green 10G Link.\u003cbr\u003eTurn on Yellow on 1G Link\u003cbr\u003eLink\/Act :\u003cbr\u003eTurns on link (Green),\u003cbr\u003eBlinks on activity (Green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLEDs location:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLEDs are located on the PCB, visible via holes in the metal bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(4) SFP+ cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cbr\u003eADDITIONAL INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIf you are utilizing this card in the Netgate 1537 or 1541, you MUST add an additional 40mm case fan with at least 200 lf\/m.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePLEASE CONTACT US IF YOU ARE ADDING THIS CARD TO THE Netgate 1541 OR 1537 SYSTEM FOR ADDITIONAL REQUIRED COMPONENTS.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e* FEATURES AND THROUGHPUT ARE SUBJECT TO HARDWARE AND OPERATING SYSTEM SUPPORT.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWARRANTY AND SUPPORT INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo returns\u003c\/li\u003e\n\u003cli\u003e1 year manufacturers warranty\u003c\/li\u003e\n\u003cli\u003eAll Specifications subject to change without notice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"shop.netgate.com","offers":[{"title":"Default Title","offer_id":45664957268070,"sku":"E11","price":499.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/3173\/6166\/files\/IntelX710BM2-4port_angle_1_360x_1c418751-2820-441e-b85c-a87a5431c766.jpg?v=1782258284"},{"product_id":"intel-x710-ethernet-network-interface-card-10g-dual-port-sfp-pcie-3-0-x8","title":"Intel X710 Ethernet Network Interface Card, 10G Dual Port SFP+, PCIe 3.0 x8","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e10 GIGABIT ETHERNET CARD DUAL PORT FIBER SFP+ NETWORK INTERFACE CARD INTEL\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e X710BM2 BASED\u003c\/h3\u003e\n\u003ch4\u003eHigh Performance, Dual Port 10GbE Ethernet Adapter, Compatible With the Netgate\u003csup style=\"font-size: 12px;\"\u003e®\u003c\/sup\u003e 8300, 1537, and 1541. \u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"des_text\"\u003e\n\u003cp\u003eThis 10 Gigabit Ethernet Dual Port SFP+ Computing PCI Express Network Interface Card offers simple integration into any PCI Express X8 slot to interface with 10Gigabit networks. The performance is optimized so that system I\/O is not the bottleneck in high-performance networking applications. Based on the Intel X710 Ethernet controller, the card has a fully integrated Gigabit Ethernet Media Access Control (MAC) and SFI Interface.\u003c\/p\u003e\n\u003cp\u003eIn addition to managing MAC and PHY Ethernet layer functions, the controller manages PCI Express packet traffic across its transaction, link, and physical\/logical layers. Using hardware acceleration, the controller offloads tasks from the host, such as TCP\/UDP\/IP checksum calculations and TCP segmentation.\u003c\/p\u003e\n\u003cp\u003eThis 10 Gigabit Ethernet PCI-Express Network Interface Card is the ideal solution for implementing multiple network segments, mission-critical high-powered networking applications, and environments within high-performance servers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKEY FEATURES:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports Direct Attached Copper cable\u003c\/li\u003e\n\u003cli\u003eSFP+ approved transceivers\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport for jumbo frame up to 9.5KB\u003c\/li\u003e\n\u003cli\u003eFlow control support\u003c\/li\u003e\n\u003cli\u003ePriority Flow Control (draft IEEE 802.1Qbb)\u003c\/li\u003e\n\u003cli\u003eEnhanced Transmission Selection (draft IEEE802.1az)\u003c\/li\u003e\n\u003cli\u003eStatistics management and RMON\u003c\/li\u003e\n\u003cli\u003e802.1q VLAN support\u003c\/li\u003e\n\u003cli\u003eDCB\/DCB-X support\u003c\/li\u003e\n\u003cli\u003eMessage Signal interrupts (MSI-X)\u003c\/li\u003e\n\u003cli\u003eStorage – Enabling competitive performance with native OS intelligent offload solutions, including NAS, iSCSI and FCoE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHost Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePCI Express GEN3 X8 lanes\u003c\/li\u003e\n\u003cli\u003eSupport PCI Express Base Specification 3.0 (8GT\/sec)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLAN and Virtualization Features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Virtualization offloads for VXLAN and NVGRE\u003c\/li\u003e\n\u003cli\u003eUnified Networking Providing a single wire for LAN and storage: NAS (SMB, NFS) and SAN (iSCSI, FCoE)\u003c\/li\u003e\n\u003cli\u003eVirtual Bridging Support – VEPA\/802.1Qbg, BPE\/802.1Qbh\u003c\/li\u003e\n\u003cli\u003ePhysical Functions – Up to 8 per port, up to 16 per device\u003c\/li\u003e\n\u003cli\u003eSupport for 128 Virtual Device Queues (VMDq) per port\u003c\/li\u003e\n\u003cli\u003eHardware Queue Pairs – Up to 1.5K (non-RDMA); up to 256K (RDMA)\u003c\/li\u003e\n\u003cli\u003eVirtualization – Alleviating hypervisor I\/O bottlenecks by providing flow separation for Virtual Machines (VMs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTCP\/IP\/L2 features*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReceive Side Scaling (RSS)\u003c\/li\u003e\n\u003cli\u003eLarge Send Offload (LSO)\u003c\/li\u003e\n\u003cli\u003eTCP\/UDP\/IP\/SCTP Checksum Offload\u003c\/li\u003e\n\u003cli\u003eIPV4, IPV6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSPECIFICATION:\u003c\/h3\u003e\n\u003ctable border=\"1\" cellspacing=\"1\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eSFP+ 10GIGABIT ETHERNET TECHNICAL SPECIFICATIONS ADAPTERS:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP+ (Small Form Factor Pluggable) supports:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFI interfaces supports 10GBase-R PCS and 10 Gigabit PMA in order to connect with SFP+ to 10GBase-SR \/ \/ 1000Base-SX \/ 10GBase-LR and SFP+ Direct Attach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-SR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.5um, 160MHz\/Km 26m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 33m\u003cbr\u003e50um, 400MHz\/Km 66m\u003cbr\u003e50um, (OM2)500 MHz\/Km 82m\u003cbr\u003e50um, (OM3)2000MHz\/Km 300m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10GBase-LR SFP+:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eFiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-LR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GBase-LR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode: 10000m at 9um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10GSFP+Cu :\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper 10Gigabit Ethernet, 10GSFP+Cu (Direct Attach)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Gigabit Ethernet, 1000Base-SX (850nM LAN PHY)\u003cbr\u003eFiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd \/ 1.25GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10000Base-SX \/ 10GBase-SR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10000Base-SX:\u003c\/strong\u003e\u003cbr\u003e62.5um, 160MHz\/Km 220m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 275m\u003cbr\u003e50um, 400MHz\/Km 500m\u003cbr\u003e50um, (OM2)500 MHz\/Km 550m\u003cbr\u003e50um, (OM3)2000MHz\/Km \u0026gt;550m\u003cbr\u003e\u003cstrong\u003e10GBase-SR:\u003c\/strong\u003e\u003cbr\u003e62.5um, 160MHz\/Km 26m\u003cbr\u003e62.5um, (OM1)200MHz\/Km 33m\u003cbr\u003e50um, 400MHz\/Km 66m\u003cbr\u003e50um, (OM2)500 MHz\/Km 82m\u003cbr\u003e50um, (OM3)2000MHz\/Km 300m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eIEEE Standard \/ Network topology:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Gigabit Ethernet, 1000Base-LX (1310nM LAN PHY)\u003cbr\u003eFiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125GBd \/ 1.25GBd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-LX \/ 10GBase-LR SFP+:\u003cbr\u003eCables and Operating distance Up to:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10000Base-LX:\u003c\/strong\u003e\u003cbr\u003eSingle-Mode: 5000m at 9um\u003cbr\u003e\u003cstrong\u003e10GBase-LR:\u003c\/strong\u003e\u003cbr\u003eSingle-Mode: 10000m at 9um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000Base-T SFP:\u003cbr\u003eIEEE Standard \/ Network topology:\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000BASE-T Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOPERATING SYSTEMS SUPPORT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating system support:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows\u003cbr\u003eLinux\u003cbr\u003eFreeBSD\u003cbr\u003eVMware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eGENERAL TECHNICAL SPECIFICATIONS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Standard:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI-Express Base Specification Revision 3.0 ( 8 GTs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoard Size:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow profile short add-in card: 145.542mm X 64.389mm (5.730”X 2.535”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCI Express Card Type:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX8 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn Board Connector Voltage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12V +\/-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCI Connector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX8 Lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControllers:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntel X710BM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHolder:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C – 45°C (32°F – 113°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C–65°C (-40°F–149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Certifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCC 47CFR Part 15:2013, Subpart B Class B\u003cbr\u003eConducted emissions\u003cbr\u003eRadiated emissions\u003cbr\u003eEN 55022: 2010, Class B\u003cbr\u003eConducted disturbance at mains terminals\u003cbr\u003eConducted disturbance at telecommunication port\u003cbr\u003eRadiated disturbance\u003cbr\u003eEN 61000-3-2: 2006+A1(09)+A2(09)\u003cbr\u003eHarmonic current emissions\u003cbr\u003eEN 61000-3-3: 2008\u003cbr\u003eVoltage fluctuations and flicker\u003cbr\u003eEN 55024: 2010\u003cbr\u003eImmunity to electrostatic discharge (ESD)\u003cbr\u003eRadiated immunity to radio frequency electromagnetic field\u003cbr\u003eConducted immunity to electrical fast transients \/ bursts (EFT\/ B)\u003cbr\u003eConducted immunity to voltage surges\u003cbr\u003eConducted immunity to disturbances induced by radio frequency field\u003cbr\u003eConducted immunity to voltage dips and short interruptions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eLEDS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLEDs:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(2) LEDs per port\u003cbr\u003eLink Speed:\u003cbr\u003eTurns on Green 10G Link.\u003cbr\u003eTurn on Yellow on 1G Link\u003cbr\u003eLink\/Act :\u003cbr\u003eTurns on link (Green),\u003cbr\u003eBlinks on activity (Green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLEDs location:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLEDs are located on the PCB, visible via holes in the metal bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(2) SFP+ cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cbr\u003eADDITIONAL INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIf you are utilizing this card in the Netgate 1537 or 1541, you MUST add an additional 40mm case fan with at least 200 lf\/m.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePLEASE CONTACT US IF YOU ARE ADDING THIS CARD TO THE Netgate 1541 OR 1537 SYSTEM FOR ADDITIONAL REQUIRED COMPONENTS.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e* FEATURES AND THROUGHPUT ARE SUBJECT TO HARDWARE AND OPERATING SYSTEM SUPPORT.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWARRANTY AND SUPPORT INFORMATION:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo returns\u003c\/li\u003e\n\u003cli\u003e1 year manufacturers warranty\u003c\/li\u003e\n\u003cli\u003eAll Specifications subject to change without notice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"shop.netgate.com","offers":[{"title":"Default Title","offer_id":45664960807014,"sku":"E09","price":299.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/3173\/6166\/files\/IntelX710BM2-2port_angle.jpg?v=1782258342"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/3173\/6166\/collections\/T520-SO-CR.gif?v=1759265393","url":"https:\/\/shop.eu.netgate.com\/collections\/expansion-cards.oembed","provider":"Netgate EU","version":"1.0","type":"link"}